亚州一区二区三区中文字幕国产精品-日韩人妻一区二区三区蜜桃视频-亚洲中文字幕久久无码精品-午夜精品亚洲一区二区三区嫩草-日韩人妻一区二区三区蜜桃视频-国产一区二区精品高清在线观看-国产欧美日韩综合精品一区二区

產品展廳收藏該商鋪

您好 登錄 注冊

當前位置:
世聯博研(北京)科技有限公司>供求商機>MI-411 MI-413-針式組合PH微電極
MI-411 MI-413-針式組合PH微電極
返回列表頁
  • MI-411   MI-413-針式組合PH微電極

舉報
貨物所在地: 北京北京市
地: 美國
更新時間: 2025-04-15 21:00:08
期: 2025年4月15日--2025年10月15日
已獲點擊: 230
在線詢價收藏產品

(聯系我們,請說明是在 化工儀器網 上看到的信息,謝謝?。?/p>

產品簡介

針式組合PH微電極
The microelectrode is ready to use. Carefully unwind the tape and remove the probe from the
protective glass tube. The white translucent sleeve, which covers the hole, should be moved
down

詳細介紹

針式組合PH微電極

Calibration
The electrode can be held by hand when measuring pH. It has been standardized in two (2) pHbuffers. Follow the procedure recommended by the manufacturer of your pH meter forcalibration.

針式組合PH微電極

Optimum Response Time: Optimum response time will be obtained after the probe has been
exercised in two (2) buffer solutions. Fill one beaker with a pH 4.01 buffer or equivalent and a
second beaker with a pH 6.86 buffer or equivalent. Hold the microelectrode and touch the pH 4
.01 buffer surface allowing 5 seconds for equilibration, and then touch the pH 6.86 buffer surface
in the same0 manner. Do this several times. It is not necessary to rinse the probe with distilled
water because the carry-over is negligible

針式組合PH微電極

Handling
The outer reference chamber of the microelectrode can be refilled when necessary with the 3 M
KCl solution, using the bulb pipette. Hold the electrode at a 60 degree angle (approx.) and
slowly insert the tip into the fill hole of the electrode.
Be careful not to apply pressure against the inner glass capillary tube.
Slowly fill the reference chamber. If filling is done too quickly, air may be trapped in the
chamber causing reference solution to squirt out of the fill hole instead of entering and filling the
reference chamber.
Cleaning
When using the microelectrode in solutions containing protein, it should be soaked in an enzyme
cleaning solution such as Terg-a-zyme (Alconox, Inc.) or a chromic/sulfuric acid glass cleaning
solution for a couple of minutes after each use to remove the protein from the glass and the
reference junction. This will prolong the useful life of the microelectrode

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功!我們將在第一時間回復您~

對比框

產品對比 產品對比 聯系電話 二維碼 意見反饋 在線交流

掃一掃訪問手機商鋪
86-010-67529703
在線留言
主站蜘蛛池模板: 稻城县| 信丰县| 德格县| 鄂尔多斯市| 崇义县| 青河县| 泰顺县| 大荔县| 光泽县| 库尔勒市| 九龙县| 嘉禾县| 桦川县| 文水县| 科技| 西贡区| 大同县| 金华市| 龙口市| 堆龙德庆县| 当阳市| 鹤庆县| 全南县| 固阳县| 蒙城县| 高碑店市| 济宁市| 龙川县| 芮城县| 长武县| 谢通门县| 古蔺县| 酒泉市| 紫云| 报价| 玉山县| 扶绥县| 怀宁县| 内江市| 太仆寺旗| 特克斯县|