FULLRIVER電池制造有限公司成立于1995年。FULLRIVER自豪地作為英超質量的鉛酸電池制造商在中國贏得了世界聲譽。FULLRIVER專業生產閥控式密封鉛酸蓄電池鉛酸蓄電池,包括FULLRIVER的高性能直流深循環范圍。 FULLRIVER所有的電池是免維護的,非危險品和非溢漏的,提供一個清潔和綠色替代傳統電池的濕/被淹的危險。不像許多的電池生產商,FULLRIVER控制整個制造過程,從電網鑄造及板粘貼到zui后的組裝。這一點的重要性不能被夸大,它確保全面質量控制。 FULLRIVER已經獲得了質量保證認證,包括*,UL,CE和TUV認證的質量生產體系。 FULLRIVER生產的BCI,DIN和JIS包括各種規格的電池。今天,FULLRIVER的制造工廠占地面積80萬平方尺,產生廣泛6,8和12伏的電池。
A brief history of Fullriver Battery Mfg. Co., Ltd.
Product development…
Fullriver Battery Manufacture Co., Ltd. was founded in 1995 and launched the HGL series. The HGL series batteries are mainly for general use purposes, i.e. low power UPS, Security & Alarm Systems, Emergency Lighting, Office machines, etc.
2、充電限流。采取先恒流后恒壓的充電方式。充電初期,充電電流較大,UPS根據所配置的蓄電池電池容量,自動將充電電流限制在0.1~0.2C,對蓄電池進行恒流充電,確保蓄電池充電時安全快速。當蓄電池容量達到80%以后,UPS轉為浮充電壓對蓄電池進行恒壓充電。
3、后備時間顯示及低電壓報警。當UPS由于各種原因切換到蓄電池供電時,用戶需要及時地了解系統的后備時間,且采取相應的措施。當蓄電池電壓降到低*,報警通知用戶,然后自動關機以防止蓄電池深度放電。
4、溫度補償。環境溫度變化時,必須對浮充電壓進行校正,校正系數為18mV/℃(標稱12V的電池)。為簡單計,可以分級校正。
電池靜置時,溫度太高,電池的自放電加劇。電池使用條件推薦為20℃~25℃,溫度太低,電池放電容量降低,充電接受能力下降。溫度太高,反應加劇,導致失水,極板腐蝕加劇。電池的充電電壓通過溫度補償來改變,溫度高時,充電電壓降低,使電池處于*浮充狀態。
因此,保證電池服務*方案是將環境溫度控制在20℃~25℃,控制放電次數、放電深度、放電和充電電流以及定時充放電的周期。
結束
The normal voltages for the HGL series are 6V and 12V; the capacity is ranged from 0.8Ah to 260Ah.
In 2001, the HGXL series was launched. This series is a 2V stationary maintenance-free battery, designed as high capacity, long life and high power batteries. These are mainly used for high capacity UPS systems, ecommunications and solar battery systems applications. The capacity of this series is ranged from 50 AH to 3000 AH.
In 2003, the HGHL series was launched. This series performs well in both high rate discharge and float service applications. This series was specially designed for UPS standby power supply. It is also available for other float service applications, such as emergency power supply, communication power supply, etc. the power of this series is ranged from 35W to 910W.
In 2004, the FAT series and the DC series were launched .The FAT series also has the characteristics of high rate discharge. They are widely used in UPS systems and ecommunications. The FAT series features front terminal connections for fast and easy installation and maintenance. The monobloc's compact design is suitable for 19", 23"and ETSI racking. The capacity of FAT series is ranged from 55Ah to 175Ah.
The DC series is specially designed and used for deep cycle applications, which may require many more cycles. This series also has excellent recovery from deep discharge. The DC series is mainly used in golf trolley, golf caddy, forklift, electric wheelchairs, floor cleaning machines, marine,
|
Based on their over 15 years of experience in the lead acid battery industry, technicians at FULLRIVER have become highly capable of designing and manufacturing customer-oriented batteries. After numerous experiments, FULLRIVER engineers have invented proprietary grid alloy formula and lead plaster formula. Combined with the advanced plate curing techniques, these formulae ensure FULLRIVER batteries to have better performance than most of their peer products in the market.
In order to sustain our rapid growth, FULLRIVER BATTERY is constantly looking for hard-working and customer-oriented people to join us. We particularly need people in electrochemistry, semiconductor chip packaging, industrial management and finance area.
We offer right candidates with great career opportunities, competitive salary, and health benefits.
For job inquiries, please send your resumes to:
(一)、了解弱電
弱電機房也叫弱電間。所謂弱電是針對電力、照明用電相對而言的。通常情況下,把電力、照明用的電能稱為強電;而把傳播信號、進行信息交換的電能稱為弱電。強電的處理對象是能源(電力),其特點是電壓高、電流大、功耗大、頻率低,主要考慮的問題是減小損耗、提高效率;
弱電工程包括電視工程、通信工程、消防工程、保安工程、影像工程等等和為上述工程服務的綜合布線工程。弱電是針對強電而言的。強電=(380/220)、高壓不管。弱電井是用來敷設弱電線路(纜)的一個(應該說是)通道。弱電井在的樓層會設制檢查口,方便給專業工作人員檢查弱電線路(纜)用的。弱電線路(纜)在弱電井里敷設即可以保護弱電線路(纜)減少人為的破壞,又可方便專業施工人員定時檢查維護,而且線路(纜)從弱電井走,不會影響大樓的整體影響,比較美觀。弱電也不僅僅是指通訊,其實有線電視線(纜)、消防報警線(纜)等等都屬于弱電。
(二)、弱電的特點
弱電的處理對象主要是信息,即信息的傳送與控制,其特點是電壓低、電流小、功率小、頻率高,主要考慮的問題是信息傳送的效果,如保真度、速度、廣度和可靠性等。
(三)、弱電機房
向建筑專業提供各種智能化系統控制系統的的機房都可以稱為弱電機房。弱電機房的配置要求,一般工程主要弱電機房有2個,一個是消控、監控、廣播、BAS、BMS作為管理的機電設備控制中心,;一個是計算機網絡中心機房、總機房,作為信息控制中心。前者一般設置于底層,后者一般設置于二、三層。其它還有有線電視機房(底層)、衛星電視機房(屋頂機房層)。另外對于不同的智能化子系統配置還要有一些控制室:如考慮設置大屏幕顯示系統,會議視頻系統,同聲傳譯系統,停車場管理系統,一卡通系統等。
1、弱電機房標準
包含要素有:中心機房的組成、建筑裝修、供電系統、接地防雷系統、空調系統、照明系統、消防報警系統、安防系統、綜合布線與網絡系統等。
2、中心機房組成
1)中心機房由主機房和輔助房間組成。主機房:放置各類服務器、主要網絡設備、網絡配線架(機柜)等。輔助房間一般包括:UPS電源間、空調控制室、滅火鋼瓶間、監控室、信息管理人員辦公室和維修室。主機房必須是房間,輔助房間可根據實際情況適當合并。
2)機房管理員辦公室、維修室必須與主機房分離。
3、弱電機房建筑裝修
為保障網絡設備的高安全性、高可靠性,機房建筑面積必須達標(B級主機房要求zui小使用面積不得小于40平方米);機房必須具備防塵、防潮、抗靜電、阻燃、絕緣、隔熱、降噪音的物理環境;機房功能區域分隔要清晰明了、便于識別和維護。
4、弱電機房的主要組成部分。
(1)、弱電機房供電系統
a)、保證服務器、網絡設備及輔助設備安全穩定運行,計算機供電系統必須達到一類供電標準,即必須建立不間斷供電系統(B級機房市電停電時,不間斷電源系統主機電源實際輸出功率宜大于后端負載1.5倍,滿負荷運轉時間不得小于120分鐘)。
b)、信息系統設備供電系統必須與動力、照明系統分開。(B級機房供電系統要求:頻率,50Hz;電壓,380V/220V;相數,三相五線或三相四線制/單相三線制;穩態電壓偏移范圍220v(-10~+10%);穩態頻率偏移范圍,50Hz(-0.5~+0.5%)。
c)電力布線要求:機房UPS電源要采用獨立雙回路供電,輸入電流應符合UPS輸入端電流要求;將市電不穩定性對機房產生的影響降低到zui低;靜電地板下的供電線路置于管內,分支到各用電區域,向各個用電插座分配電力,防止外界電磁*系統設備;線路上要有標帖表明去向及功能,保證維修方便、操作靈活。
(2)、弱電機房防雷接地
a.)機房內各個系統都有獨自的接地要求,按功能分有交流工作地、安全保護地、靜電地、屏蔽地、直流地、防雷地等。
b.)中心機房的接地系統:必須安裝室外的獨立接地體;直流地,防靜電地采用獨立接地;交流工作地、安全保護地采用電力系統接地;不得共用接地線纜,所有機柜必須接地。(B級機房系統交流工作地的接地電阻不應大于4歐姆;安全保護地的接地電阻不應大于4歐姆;防雷保護。
地的接地電阻不應大于4歐姆;直流地,防靜電地接地電阻不應大于1歐姆;實際接地要求按照計算機設備具體要求確定)。
c.)機房防雷體系:主要包括建筑物內、外兩層防護措施和機房進出線防護措施。外部防護主要由建筑物自身防雷系統來承擔;所有由室外直接接入機房金屬信息線纜,必須作防浪涌處理;鎧裝光纖金屬保護層進行可靠接地;所有弱電線纜不裸露于外部環境;弱電橋架使用扁銅軟線帶跨接,進行可靠接地;機房電源系統至少二極防浪涌處理;重要負載末端防浪涌處理。
(3)、弱電機房空調系統
通過該系統保持機房內相對穩定的溫度和濕度,使機房內的各類設備保持良好的運行環境,確保系統可靠、穩定運行。(B級機房空調系統要求:全年溫度,18~25℃;相對濕度,35~65%;溫度變化率,
由于網頁資源有限,具體電池型號、參數、價格咨詢請致電。
另外我們還為客戶提供技術咨詢服務,說出您的負載、延時時間等,
我們會有專業的工程師為您提供ups電源、電池解決方案,讓您真正的后顧無憂!