產(chǎn)品簡(jiǎn)介
中國(guó)臺(tái)灣BB蓄電池BP33-12 12V33AH報(bào)價(jià)
詳細(xì)介紹
中國(guó)臺(tái)灣BB蓄電池BP33-12 12V33AH報(bào)價(jià)
中國(guó)臺(tái)灣BB蓄電池BP33-12 12V33AH報(bào)價(jià)
Zelus, A classic GEL battery
Zelus is a VRLA battery with a gelified electrolyte; the sulfuric acid is mixed with silica fume, which makes the resulting mass gel-like and immobile. GEL batteries virtually eliminate the electrolyte evaporation, spillage (and subsequent corrosion Issues) common to the wet-cell battery, and more features like greater resistance to extreme temperatures, shock, and vibration. The valve regulation system allows for gas to be expelled. They are the same as wet (non-sealed) batteries except that the antimony in the lead plates is replaced by calcium. This preserves the mechanical characteristics but renders the construction far less prone to gassing.
我們?cè)敢馀c朋友們攜手共進(jìn),共同發(fā)展,創(chuàng)造輝煌的未來(lái)。
公司于1996年10月份獲得DNV的ISO 9002質(zhì)量體系認(rèn)證, 又在1998年12月獲得ISO 9001質(zhì)量體系認(rèn)證, 2001獲得ISO14000環(huán)境體系認(rèn)證。產(chǎn)品歐美,東南亞等許多國(guó)家及地區(qū)。抑制UPS電源諧波方法
方法一、采用6脈沖UPS電源和有源諧波濾波器,輸入電流諧波《5%(額定負(fù)載),輸入功率因數(shù)0.95。這種配置,雖然輸入指標(biāo)非常好,但是技術(shù)仍然不是很成熟,存在誤補(bǔ)償、過(guò)補(bǔ)償?shù)葐?wèn)題,導(dǎo)致主輸入開(kāi)關(guān)誤跳閘或損壞等現(xiàn)象。
方法二、采用12脈沖UPS電源+11次諧波濾波器,如UPS電源整流裝置為三相全控橋12脈沖整流器,加11次諧波濾波器后減小到4.5%以下,可基本*消除諧波電流含量對(duì)電網(wǎng)的危害,價(jià)格相對(duì)有源濾波器要便宜。
方法三、采用移相變壓器+6脈沖整流器的假12脈沖方案,其組成由2臺(tái)6脈沖整流器UPS電源拼湊成。
方法四、采用6脈沖UPS電源和5次諧波濾波器,如果UPS電源整流裝置為三相全控橋6脈整流器,由整流裝置產(chǎn)生的諧波占所有諧波的近25-33%加5次諧波濾波器后減小到10%以下,輸入功率因數(shù)0.9,可局部減小諧波電流對(duì)電網(wǎng)的危害。此種配置,輸入電流諧波仍然會(huì)偏大,對(duì)發(fā)電機(jī)容量配比要求為1:2以上,并存在導(dǎo)致發(fā)電機(jī)輸出異常升高的隱患。
產(chǎn)品用途
蓄電池應(yīng)用領(lǐng)域與分類:
◆ 免維護(hù)無(wú)須補(bǔ)液; ● UPS不間斷電源;
◆ 內(nèi)阻小,大電流放電性能好; ● 消防備用電源;
◆ 適應(yīng)溫度廣; ● 安全防護(hù)報(bào)警系統(tǒng);
◆ 自放電??; ● 應(yīng)急照明系統(tǒng);
◆ 使用壽命長(zhǎng); ● 電力,郵電通信系統(tǒng);
◆ 荷電出廠,使用方便; ● 電子儀器儀表;
◆ 安全防爆; ● 電動(dòng)工具,電動(dòng)玩具;
◆ *配方,深放電恢復(fù)性能好; ● 便攜式電子設(shè)備;
◆ 無(wú)游離電解液,側(cè)倒仍能使用; ● 攝影器材;
◆ 產(chǎn)品通過(guò)CE,ROHS認(rèn)證,所有電池 ● 太陽(yáng)能、風(fēng)能發(fā)電系統(tǒng);
符合國(guó)家標(biāo)準(zhǔn)?! ?nbsp;*自行車、紅綠警示燈等選擇合適的充電保護(hù)工作點(diǎn)
目前使用的伊頓UPS電源一般都是采用免維護(hù)式的密封蓄電池。充電系統(tǒng)基本上都是采用恒壓載止充電回路,該電路可以對(duì)電池設(shè)置過(guò)壓保護(hù)工作點(diǎn),對(duì)電池起到了很好的保護(hù)作用,但是不可將保護(hù)工作點(diǎn)設(shè)置的過(guò)高或過(guò)低,因?yàn)楸Wo(hù)工作點(diǎn)的高低可能直接導(dǎo)致電池的過(guò)充或者充電不足。在很多情況下由于充電保護(hù)工作點(diǎn)的選擇不當(dāng),導(dǎo)致充電對(duì)電池造成過(guò)流或過(guò)壓,使電池壽命大減,嚴(yán)重時(shí)還會(huì)導(dǎo)致電池膨脹變形,甚至爆炸,直接威脅到人身和財(cái)產(chǎn)的安全。
電池的工作環(huán)境與電池的儲(chǔ)電容量有著密切聯(lián)系,伊頓UPS電源對(duì)環(huán)境溫度的要求較高,一般為0~40℃,溫度為25℃±5%。溫度過(guò)高,逆變器將會(huì)停止工作并報(bào)警,同時(shí)也影響電池的壽命;溫度過(guò)低,將影響蓄電池的輸出能力。夏季氣溫很高,若通風(fēng)不好,設(shè)備本身運(yùn)行所產(chǎn)生的大量熱量不能及時(shí)排出,溫度將迅速上升,若超過(guò)55℃,逆變器將停止工作。溫度過(guò)高或者過(guò)低的工作環(huán)境,將直接影響伊頓UPS電源系統(tǒng)的壽命和工作性能。
BB蓄電池型號(hào)參數(shù)表:
Model | Voltage | Nominal Capacity | Weight | Terminal | Dimension | Model | ||||||||||||
15 Min W/Cell | 10hr Ah | Kg | Lbs | Standard | Optional | L | W | H | TH | |||||||||
Type | Position | Type | Position | MM | INCH | MM | INCH | MM | INCH | MM | INCH | |||||||
HR9-6 | 6 | 36 | 8 | 1.40 | 3.09 | T2 | 2 | T1 |
| 151 | 5.94 | 34 | 1.34 | 94 | 3.70 | 100 | 3.94 | HR9-6 |
HR4-12 | 12 | 16 | 3.5 | 1.40 | 3.09 | T1 | 3 | T2 |
| 134 | 5.28 | 67 | 2.64 | 60 | 2.36 | 66 | 2.60 | HR4-12 |
HR5.5-12 | 12 | 22 | 5 | 1.80 | 3.97 | T1 | 3 | T2 |
| 90 | 3.54 | 70 | 2.76 | 102 | 4.02 | 106 | 4.17 | HR5.5-12 |
HR5.8-12 | 12 | 23 | 5.3 | 1.88 | 4.15 | T1 | 3 | T2 |
| 90 | 3.54 | 70 | 2.76 | 102 | 4.02 | 106 | 4.17 | HR5.8-12 |
HR6-12 | 12 | 24 | 5.5 | 2.10 | 4.63 | T1 | 5 | T2 |
| 151 | 5.94 | 51 | 2.01 | 94 | 3.70 | 100 | 3.94 | HR6-12 |
HR8-12 | 12 | 32 | 7 | 2.60 | 5.73 | T2 | 5 | T1 |
| 151 | 5.94 | 65 | 2.56 | 94 | 3.70 | 100 | 3.94 | HR8-12 |
HR9-12 | 12 | 36 | 8 | 2.75 | 6.06 | T2 | 5 | T1,B0 |
| 151 | 5.94 | 65 | 2.56 | 94 | 3.70 | 100 | 3.94 | HR9-12 |
HR15-12 | 12 | 60 | 13 | 4.20 | 9.26 | T2 | 5 | T1 |
| 151 | 5.94 | 98 | 3.86 | 94 | 3.70 | 98 | 3.86 | HR15-12 |
HR22-12 | 12 | 88 | 20 | 6.50 | 14.33 | B1 | 7 | T2,I1 | 6 | 181 | 7.13 | 76 | 2.99 | 166 | 6.54 | 166 | 6.54 | HR22-12 |
HR33-12 | 12 | 132 | 31 | 10.00 | 22.05 | B1 | 7 | T2,I1 | 9 | 175 | 6.89 | 166 | 6.54 | 125 | 4.92 | 125 | 4.92 | HR33-12 |
HR40-12S | 12 | 160 | 38 | 12.10 | 26.68 | B7 | 8 |
|
| 195 | 7.68 | 129 | 5.08 | 155 | 6.10 | 179 | 7.05 | HR40-12S |
HR40-12H | 12 | 160 | 38 | 12.10 | 26.68 | B7 | 8 | I2 |
| 210 | 8.27 | 129 | 5.08 | 168 | 6.61 | 179 | 7.05 | HR40-12H |
HR40-12F | 12 | 160 | 38 | 12.10 | 26.68 | B7 | 8 | I2 |
| 195 | 7.68 | 129 | 5.08 | 168 | 6.61 | 179 | 7.05 | HR40-12F |
HR50-12 | 12 | 200 | 48 | 15.30 | 33.74 | B2 | 7 | I1,I2 |
| 197 | 7.76 | 165 | 6.50 | 171 | 6.73 | 171 | 6.73 | HR50-12 |
HR75-12 | 12 | 300 | 73 | 24.75 | 54.57 | B5 | 15 | I2 |
| 350 | 13.78 | 166 | 6.54 | 174 | 6.85 | 174 | 6.85 | HR75-12 |
全面質(zhì)量保證
BB已經(jīng)通過(guò)德國(guó)TUV機(jī)構(gòu)ISO9001、ISO9002兩項(xiàng)質(zhì)量認(rèn)證認(rèn)證及美國(guó)UL認(rèn)證。產(chǎn)品全部經(jīng)美國(guó)C.C.D.S電腦自動(dòng)化系統(tǒng)輛次*充放電檢驗(yàn)。
環(huán)保先鋒隨著工業(yè)文明的不斷進(jìn)步,現(xiàn)代工業(yè)對(duì)電力質(zhì)量的要求越來(lái)越高,為了保障工業(yè)過(guò)程以及日常工作的連續(xù)性,UPS電源應(yīng)運(yùn)而生,成功的解決了電力中斷以及電力質(zhì)量差的問(wèn)題,廣泛地應(yīng)用于工業(yè)控制、通信、醫(yī)療、計(jì)算機(jī)、交通、銀行、證券、政府、教育、安防監(jiān)控等等的各行各業(yè)當(dāng)中。
(一)UPS電源產(chǎn)生諧波的危害
在日常的使用中,由于UPS電源的諧波帶來(lái)的危害在于幾個(gè)方面:
1、UPS電源諧波可能會(huì)造成電流表、電壓表、功率表、電能表測(cè)量誤差,使照明設(shè)施壽命縮短。
2、使得配電線路的損耗變大、發(fā)熱、縮短絕緣體的壽命,甚至有可能引起短路或者火災(zāi)。
3、對(duì)斷路器、漏電保護(hù)器、繼電器等保護(hù)、自控裝置等儀器產(chǎn)生干擾,造成誤動(dòng)作。使電動(dòng)機(jī)產(chǎn)生附加的損耗和發(fā)熱、產(chǎn)生脈動(dòng)轉(zhuǎn)矩和噪音。
4、對(duì)臨近的通訊線路產(chǎn)生靜電干擾和電磁干擾,引起配電系統(tǒng)靜電,可能會(huì)引起補(bǔ)償電容器發(fā)生串/并聯(lián)諧振。
5、由于諧波,使電壓突變而造成電子設(shè)備損壞、出現(xiàn)誤動(dòng)作,沈陽(yáng)穩(wěn)壓電源影響計(jì)算機(jī)程序正常運(yùn)行。造成數(shù)據(jù)丟失,甚至損壞硬件,引起樓宇自動(dòng)化、消防報(bào)警系統(tǒng)、安全防范系統(tǒng)誤動(dòng)作,甚至無(wú)法工作。
本公司主要銷售一下產(chǎn)品: